Environment Monitoring Sensors Manufacturer

Atmospheric Pressure Sensor

This atmospheric pressure sensor adopts an imported high-precision measuring unit. The device has built-in high-precision temperature compensation, high stability, low drift, and high repeatability. It can be easily fixed to the wall by wall-mounted housing. It is suitable for places where atmospheric pressure measurement is required, such as altimeters, agricultural greenhouses, weather station, archives, etc.

  • Model: RS-QY-*-2D-LCD-EX
  • MOQ: 1 PCS
  • Delivery date: within 24 hours
  • Price: USD 28.30

Renke Atmospheric Pressure Sensor

RS-QY-*-2D-LCD-EX atmospheric pressure sensor measures a wide range of 0-120kPa air pressure, which can be applied to various altitudes. The measured data can be directly displayed on the LCD screen or uploaded to the free cloud platform via RS485 signal. Optional built-in temperature and humidity sensor can be used to monitor atmospheric pressure, temperature and humidity at the same time. The back of the atmospheric pressure sensor housing is equipped with a slide rail mounting plate, which supports wall mounting or guide rail mounting.

OutputRS4854~20mA/0~5V/0~10V
Power supply10~30V DC
Max. power consumption≤0.5W1.2W
Measure range0~120kPa
Accuracy±0.15kPa@25℃ 101kPa
Operating temperature-40℃~+60℃, 0%RH~95%RH (non-condensing)
Long-term stability-0.1kPa/year
Response time≤2s
Load capacityresistance ≤ 250Ω, current ≤ 600Ω

Our atmospheric pressure sensors

Atmospheric Pressure Sensor Wiring

The wide voltage power input is 10~30V. When wiring the 485 signal line, please note that the A/B lines cannot be connected in reverse, and the addresses of multiple devices on the bus cannot conflict.

Wiring Instructions

Circuit identificationDescription
Power supplyVCCPositive power supply (10~30V DC)
GNDNegative power supply
Communication485A485-A
485B485-B
RS485 atmospheric pressure sensor

Register Address

Register addressPLC or configuration addressContentSupported function codeDescription
0000 H40001Air pressure (unit: kPa)0x03/0x04Real-time value (expanded 10 times)
0051 H40082Air pressure calibration value0x03/0x04/0x06Integer (expanded 10 times)
07D0 H42001Device address0x03/0x04/0x061~254 (factory default 1)
07D1 H42002Device baud rate0x03/0x04/0x060 represents 2400
1 represents 4800
2 represents 9600
3 represents 19200
4 represents 38400
5 represents 57600
6 represents 115200
7 represents 1200

Power supply wiring

Wide voltage 10~30V DC power input. For 0-10V output type equipment, only 24V power supply can be used.

Output interface wiring

The standard equipment has 1 independent analog output. It is suitable for both three-wire and four-wire systems.

Wiring Instructions

Circuit identificationDescription
Power supplyVCCPower supply positive
GNDPower supply negative/signal negative
OutputTHReserved
RHAtmospheric pressure signal positive
Analog atmospheric pressure sensor

Current output signal conversion calculation

For example, the range is 0~120kpa, 4~20mA output, when the output signal is 12mA, calculate the current air pressure value. The span of this air pressure range is 120kpa, expressed by 16mA current signal, 120kpa/16mA=7.5kpa/mA, that is, 1mA current represents a pressure change of 7.5kpa, the measured value is 12mA-4mA=8mA, 8mA*7.5kpa/mA=60kpa. 60+0=60kpa, the current air pressure is 60kpa.

 

Voltage output signal conversion calculation

For example, the range is 0~120kpa, 0-10V output, when the output signal is 5V, calculate the current air pressure value. The span of this air pressure range is 120kpa, which is expressed by a 10V voltage signal. 120kpa/10V=12kpa/V, that is, a voltage of 1V represents a pressure change of 12kpa, and the measured value is 5V-0V=5V.5V*12kpa/V=60kpa. 60+0=20kpa, and the current air pressure is 60kpa.