Table of Contents What is conductivity in water? Conductivity in water is the ability of water to conduct electricity. It is primarily related to the
Dissolved Oxygen Meter
Our RS-LDO-N01-EX dissolved oxygen meter is a device for measuring the concentration of dissolved oxygen in water. It adopts the principle of fluorescence measurement, does not consume oxygen, and does not require electrolytes. The dissolved oxygen measurement range is 0~20mg/L. Built-in temperature transmitter with automatic temperature compensation function.
- Model: RS-LDO-N01-EX
- MOQ: 1 PCS
- Delivery date: within 24 hours
- Price: $88
About - Dissolved oxygen meter
Our dissolved oxygen sensors are divided into two types: seawater and freshwater. The calibration function provides a simpler and more convenient way to calibrate. Water dissolved oxygen meter can be widely used in water treatment, aquaculture, rivers, lakes, and seawater quality monitoring industries.
Parameters
Power supply: DC 10~30V
Power consumption: 0.2W
Measuring principle: fluorescence method
Measuring range: 0~20mg/L (0~200% saturation)
Measurement error: ±3%FS; ±0.5°C (25°C)
Resolution: 0.01mg/L; 0.1%; 0.1℃
Response time: ≤60sec
Equipment working conditions: 0~40℃
Output mode: RS485
Fluorescent film life: 1 year in normal use
Storage conditions: -10~60℃
Electrode wire length: default 5m
Shell material: polyoxymethylene (POM), stainless steel
Features
1. Dissolved oxygen measurement range is 0~20mg/L (0~200% saturation).
2. The Modbus communication address can be set, and the baud rate can be modified.
3. The dissolved oxygen sensor uses a wide voltage power supply, DC 10~30V can be.
4. The principle of fluorescence measurement is adopted, no oxygen is consumed, and no electrolyte is required.
5. Free cloud platform for the data view.
Working Principle - DO meter
Fluorescence Dissolved Oxygen: Based on the quenching principle of active fluorescence by specific substances in physics.
By measuring the phase difference between the excited red light and the reference light, and comparing it with the internal calibration value, the concentration of oxygen molecules can be calculated.
Calibration method - Dissolved oxygen meter
Zero oxygen standard solution preparation: prepare a beaker, pour 200mL of distilled water into the cup, then add anhydrous sodium sulfite, stirring while adding, wait until the anhydrous sodium sulfite is saturated, at this time the standard solution is considered close to 0 oxygen. 100% oxygen environment preparation: prepare a beaker, pour 200mL pure water (or distilled water) into the cup, add the air pump, and fully expose the solution to air (at least 30 minutes). Note: If the site conditions really do not allow or the use requirements are not high, you can also directly put the sensor in the air (calibration accuracy will be deviated).
Other water quality sensors
Related blogs
What is dissolved oxygen? Dissolved oxygen (DO) refers to molecular oxygen dissolved in water. The unit is mg/L, which means how many milligrams oxygen in
Long-term rainfall and melting snow have raised water levels and flooded city roads, causing flooding. Frequent and extreme flooding is inevitable and endangers community safety.
Everyone knows that the choice of water quality sensors is very important. In water measurement, the ph sensor is one of the important tools. However, there are
Natural disasters such as floods and heavy rains pose threats to lives and property around the world. Without a proper flood monitoring system, these natural
Table of Contents Water is the source of life, and human beings cannot do without water in life and production activities. The quality of drinking
Table of Contents Have you or your friend experienced a broken water pipe, water accumulation in the kitchen or bathroom? Water is the most common
Table of Contents What is IoT? IoT is the “Internet of things“. It is an extended and expanded network based on the Internet. It combines
Table of Contents What is a water level sensor? The water level sensor is a device that measures the liquid level in a fixed container